Real-time access to your data and 24/7 monitoring from anywhere in the world.
Multi-year data history.
Easy to communicate with your stakeholders.
Free software updates and improvements.
Controller compatible probes
This is a list of all compatible probes that can be connected to the controller and a short description of their function.
- 2004-10K Temperature probe (black cap)
- Temperature probe with a temperature range of -58.0 to 140.0 °F (-50.0 to 60.0 °C).
- HUM3 Relative humidity probe
- Relative humidity probe with a measuring range of 0 to 100 RH% (red connector)
Controller compatible modules
This is a list of all the compatible modules that can be connected to the controller and a short description of their function.
- Variable module
- GE-V4 (4 variables outputs GE-V2 (2 variables outputs)
- GE-MS10 (2 0-10volt outputs)
- Slave module
- Weather station module
- MSTAT-1 (Weather station module)
Remote access
- RF-IN2 Communication Module (Module inserted into the controller for a wireless communication with the computer interface)
Inputs listing
- Inside Temperature 1 to 16*
- Humidity Up to 4*
- Outside Temperature Up to 1
- Water Meter Up to 1
- Luxmeter Up to 4
- Opened Garage Door Up to 1
- Closed Garage Door Up to 1
- Bin Scale Up to 4
- Static Pressure Up to 1*
- Feeder Up to 1*
- Feed Auger Up to 1*
- CO2 Up to 1*
- Ammonia Up to 1*
- Poultry Scale Up to 4
- Recuperator Temperature Up to 1*
- Generic Counter Up to 4
- Energy Counter Up to 1
- Input board 8 MGCB (X1399/INPUTBOARD-8) Up to 2
Outputs listing
- Variable Stage Up to 6*
- Variable Stir Fan Up to 6*
- On/Off Stir Fan Up to 6*
- On/Off Stage Up to 10*
- Heater Up to 6*
- Variable Heater Up to 6*
- Sprinkler/Mist Up to 1*
- Clock Up to 4*
- Inflatable Curtain (1-4 blowers) Up to 8*
- Air Inlet Up to 8*
- Light Up to 1*
- Alarm 1
- Generic Relay Up to 4*
- Garage Door Relay Up to 1*
- Dusting Up to 1*
- Trap Doors Up to 1*
- On/Off Lights Up to 4*
- Feeder Up to 1*
- Recuperator Input Polarity Up to 1*
- Recuperator Output Polarity Up to 1*
- Recuperator Valve Up to 10*
- Recuperator Pump Up to 1*
(*By zone)
List and type of equipment compatible with the iTouch light.
(The quantity and necessary equipment depend on the various types of installations.)
- 1 Control
- Up to 2 Input Boards (X1407)
- Up to 4 REL-4 (X1307)
- Up to 4 POS-2 (X1306)
- Up to 2 Variable Boards (X1408)
- Up to 1 SL16 (Slave with up to 16 relays and 2 variables)
- Up to 4 HUM3 (Humidity Probe)
- Up to 1 SM (Weather Station)
- Up to 1 MS10 (0-10volts Module)
- Up to 2 RP16 (Toggle Switches Module)
- Up to 2 MGCB 8 Input Board (X1399)
- Up to 2 V2 or V4 (Variable Module)
- Up to 16 2004-10k Probes
- Up to 4 Lux MeterFeed Auger Up to 1*
- Up to 4 Static Pressure Probes
- Up to 4 Ammonia Sensors
- Up to 4 Press+ Boards (X1455)